<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-03 15-04-39
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 57 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 6.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 55 kHz 17392 3,9213
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,0 dBr 1,64 dBr 3,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 55 kHz MIN: 12 kHz % above 76 kHz: 3,9213 Acquired: 2024/08/03 15.03.35 Total samples: 17392 Equivalent time: 0:14:29 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 3,0 dBr MIN: -1,0 dBr AVE: 1,64 dBr % above 12,2 dBr: 0,0 Last value: 1,8 dBr (2024/08/03 15.03.35) 14.50 14.52 14.54 14.56 14.58 15.00 15.02 -1 0 1 2 3 4 Pm [dBr]